Slug Control

An ingenious way to control slugs in your garden with a little wire and a 9 volt battery.

Slugs will ruin a vegetable garden pretty fast unless some serious means of taking care of them is implemented.  The electric fence has proven to be pretty well 100% effective in my experiments to date.  The fence consists of two runs of wires spaced about 3/4 inch apart running around the perimeter of the raised bed – one wire is connected to the +ve terminal and the other to the -ve terminal of a battery. An electric current will flow through the slug if it makes contact with both wires at the same time. The resulting “shock” with usually cause the slug to turn back.

I’ve been using a 9-volt battery as the power source, the battery  lasts the whole growing season but the voltage drops to 5 volts or so by the end of the season (my measurements). It’s a good idea to check the volage once in a while to make sure the battery is still providing enough voltage (corrosion can be a problem at the battery connectors).  A few years ago when setting up a new fence I didn’t have a 9-volt battery connector so I used a multi-battery  AA holder that I had on hand.  The combined series connection of batteries gave 12 volts.  This turned out to be a bad idea as the 12 volts would more often than not kill the slugs rather than just turn them away.

The nice thing about the slug fence is that it is on duty 24-7, many other slug control methods require some kind of regular checking or resupplying.  Also, no dangerous chemicals to worry about with this setup.

My first electric fence was mounted on a low “raised” bed garden.  It was effective until the vegetation in the garden grew high enough to bend over and touch the ground – this gave the slugs the bridge they needed to reach the main feast.

The video below demonstrates how a slug typically reacts when attempting to cross the fence.  It is interesting to notice from the video that once the slug was “shocked” a number of times (by making contact with both wires) it was then conditioned to react the same way when touching just one wire (no current flow possible through the slug).

Written by: NLinventor

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s